Featured Products
RockWell Egress Window Wells
ScapeWEL Egress Window Wells
Window Well Scenes
Better Lifestyle Fold-Down Ironing Board System
Fake Landscaping Rocks and Decor
Precast Artificial Stone Pillars and Mailboxes
Milwaukee Electric Tools
DeWalt Tools & Access.
Metabo Power Tools
Panasonic Power Tools
Ridgid Pipe Tools
Greenlee-Textron
Irwin Industrial
Stanley Hand Tools
Lenox / American Saw
Wright Tools
Stabila Levels
Laser Levels
Spot-Rite Levels
ITW Redhead Anchors
Plastic Anchors and Kits
Sait / United Abrasives
Rectorseal MetaCaulk Firestop
Walter Abrasives

Diamond Blades/Core Bits
Caddy Electrical Fasteners
Ladders and Scaffolding
Truck Boxes, Ladder Racks, Jobsite Storage
Extension Cords and Temporary Lighting
Drill Bits and Machine Tools
Spray Paint, Chemicals and Lubricants
Fall Protection Gear
Safety Glasses
Safety Products
Work Gloves/Work Wear
First Aid Kits

Lockout/Tagout Kits
Slings, Lifting, Cargo Control
Anchors (Mechanical and Adhesive)
Nuts, Bolts, Screws and Fasteners
Drywall Screws and Metal Building Fasteners
U-Bolts, Eye Bolts, and Bent Wire Fasteners
Rope and Chain
Steel Banding/Poly Banding
Strut, Strut Fittings
Mechanical Hangers
Threaded Rod
Tape
Caulk and Adhesives
 

We ship nationwide!
 

Summit accepts Visa, MasterCard, and Discover Card

 

 

 
Scapewel egress window wells for your basement.  Helps make your basement useable living space.
Egress Window Wells

Egress Code

 

Section R310

EMERGENCY ESCAPE AND RESCUE OPENINGS

R310.1 Emergency escape and rescue required. Basements with habitable space and every sleeping room shall have at least one openable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Where emergency and escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section 310.3. The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall  be provided with a window well in accordance with Section R310.2.

R310.1.1 Minimum opening area. All emergency escape and rescue openings shall have a minimum net clear opening of 5 square feet (0.530 mฒ).

Exception: Grade floor opening shall have a minimum net clear opening of 5 square feet (0.465 mฒ).

R310.1.2 Minimum opening height. The minimum net clear opening height shall be 24 inches (610 mm).

R310.1.3 Minimum opening width. The minimum net clear opening width shall be 20 inches (508 mm).

R310.1.4 Operational constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools.

R310.2 Window wells. The minimum horizontal area of the window well shall be 9 square feet (0.84 mฒ), with a minimum horizontal projection and width of 36 inches (914 mm). The area of the window well shall allow the emergency escape and rescue opening to be fully opened.

Exception: The ladder or steps required by Section R310.2.1 shall be permitted to encroach a maximum of 6 inches (152 mm) into the required dimensions of the window well.

R310.2.1 Ladder and steps. Window wells with a vertical depth greater than 44 inches (1118 mm) shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or steps required by this section shall not be required to comply with the sections R311.5 and R311.6. Ladders or rungs shall have an inside width of at least 12 inches (305 mm), shall project at least 3 inches (76 mm) from the wall and shall be spaced not more than 18 inches (457 mm) on center vertically for the full height of the window well.

R310.3 Bulkhead enclosures. Bulkhead enclosures shall provide direct access to the basement. The bulkhead enclosure with the door panels in the fully open position shall provide the minimum net clear opening required by Section R310.1.1. Bulkhead enclosures shall also comply with Section R311.5.8.2.

R310.4 Bars, grills, covers and screens. Bars, grills, covers and screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided the minimum net clear opening size complies with Sections R310.1.1 to R310.1.3, and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening.

 

Click here to buy egress window wells online, or to check pricing

 

Learn More Here!

ScapeWEL Basement Egress Window Wells

Click here to get pricing information and order Scapewel basement egress window wells onlineClick here to get pricing information and order ScapeWEL online!
Click here for the ScapeWEL home pageScapeWEL home page
Click to see photos of ScapeWEL Basement Egress Window WellsSee photos of ScapeWEL Basement Egress Window Wells
Click for to learn how to determine the correct size Scapewel basement egress window wellHow to determine the correct size ScapeWEL well
Click for to see Scapewel basement egress window well sizing and measurementsScapeWEL Egress Window Well sizing and measurements (PDF file)
Click for to see Scapewel egress window well installation instructionsScapeWEL Egress Window installation instructions (PDF file)
Click to see instructions for installing the extension on 81" high ScapeWEL egress window wellsInstructions for installing the extension on 81" high ScapeWEL egress window wells (PDF file)
Click to see instructions for installing ScapeWEL's Clear Dome CoverInstructions for installing ScapeWEL's Clear Dome Cover (PDF file)
Click to see ScapeWEL Warranty and Registration FormScapeWEL Warranty and Registration Form (PDF file)
Click to see Frequently Asked Questions (FAQ's) about ScapeWEL Egress Window Wells Frequently Asked Questions (FAQ's) about ScapeWEL Egress Window Wells
Click to see IRC Building Code for egress IRC Building Code for egress 

Want to speak with us?  Call (800) 349-5808 or click here

 

Rockwell Egress Window Wells   •   ScapeWEL Egress Window Wells    •   White Steel Egress Window Wells   •   Milwaukee Electric Tools    •   Window Well Scenesฎ    •   Panasonic Power Tools   •   LifeStyle Ironing Centers   •   Precast Stone & Brick Columns   •   Precast Mailbox Enclosures   •   Fake Rocks and Outdoor Decor     •   Rectorseal Metacaulk Firestop   •   PLS Laser Level    •    Spot-Rite Level    •   Anchors and Anchoring Systems   •   Ridgid Tools   •   Greenlee Electrician Tools   •    Irwin Tools   •   Site Map   •   Links

 

ฉ2012 Summit Contractor Supply, Inc.  All Rights Reserved.
25453 State Road 2 • South Bend, IN 46619 USA
574.233.4300 • 800.349.5808 • FAX 574.233.4301
sales@summitcontractorsupply.com

Summit Contractor Supply, Inc. is a proud member of the Specialty Tools and Fasteners Distributors Association (STAFDA)